For devices that support the sampling 
 function of high-performance counter, it is possible to retrieve the count 
 value (Sampling) periodically by using Internal 
 Clock or External Clock.
It is necessary to perform sampling setting not only for using counter 
 in sampling mode but also for using a usual counter.
The sampling data is stored directly in the memory of the specified application.
In sampling mode, two or more continuous channels from channel 0 to a specified 
 channel of the counter are sampled at the same time.
Except for software start/stop, sampling can also start/stop by the rising 
 edge or falling edge of external signal. Moreover, It is possible to stop 
 sampling with specified times, or start/stop sampling when the count becomes 
 a specified value.
For sampling, except for condition setting of channel/start/clock/stop 
 mentioned above, it is also need to set items such as the buffer for storing 
 sampling data, sampling completion notification and specified time sampling 
 completion notification.
Please refer the each flowcharts as below.
| Category | Counter Type | Name of Flowchart | 
| Sampling | High-performance counter only | 
* Please refer Counter Type Specification as well.
See Also
Init and Exit Processing
Counter Operation 
 Mode Setting
Count Match Detection 
 [High-performance counter]
Hardware Event [High-performance 
 counter]
Counter Operation
Sampling Mode Setting
Sampling Condition Setting
Sampling Start
Sampling Completion
Handling Method of Sampling Buffer