Select to perform continuous analog output
AoSamplingTimes |
[-1] Can be set |
Initial value: -1 (Not change) |
Specify the number of samplings. As the number of samplings is reached, status [Output up to the specified number of data] will change to be ON
- FIFO memory
When the data remained in buffer
(Data which hasn't been output) reduce to the specified number, status
[Output up to the specified number of data] is changed to be ON
(Please note that it's not [the number of data which has been
output], which is different from RING memory)
When the status is ON, if data
is written and data remained in the buffer is over the specified number,
status is changed to be OFF
In the initial state and if terminal is not connected, when
the number of remained data reduces to 500, status [Output up to the specified
number of data] will change to be ON
- RING memory
When the data which has been
output reaches to the specified number, status [Output up to the specified
number of data] is changed to be ON
In the initial state and if terminal is not connected, when
the number of output reaches to 500, status [Output up to the specified
number of data] will change to be ON
*The range of configurable AoSamplingTimes
depends on the device
Please refer to [Device-specific
Setting List]