Setting for Stop
⑧ Specified Times Stop [ai_stop_times.vi]

 

Select when sampling stops by the specified times

 

 


Layout of IN/OUT terminal

 


IN terminal

AiStopTimes

Initial value: 1000

[Essential]
Specify the number of samplings

The number of samplings is independent of the number of channels to be used
For example, if you want to perform sampling for 1000 times by 2 channels, and get 2000 data, then you should specify [AiStopTimes] as 1000

*The upper limit of the number of sampling times that can be set varies depending on the device
 Please refer to [Device-specific Setting List]