Select for analog input
DeviceName |
Initial value: "AIO000" |
[Essential]
Specify the device name (Devicename) to use
Devicename is set and confirmed by device manager
AiRange |
[-1] Can be set |
Initial value: -1(Not change) |
Specify the analog input range
Range |
Value |
Range |
Value |
Range |
Value |
Range |
Value |
|||
±10V |
0 |
±0.25V |
8 |
0 to 10V |
50 |
0 to 0.1V |
58 |
|||
±5V |
1 |
±0.125V |
9 |
0 to 5V |
51 |
0 to 0.05V |
59 |
|||
±2.5V |
2 |
±0.1V |
10 |
0 to 4.095V |
52 |
0 to 0.025V |
60 |
|||
±1.25V |
3 |
±0.05V |
11 |
0 to 2.5V |
53 |
0 to 0.0125V |
61 |
|||
±1V |
4 |
±0.025V |
12 |
0 to 1.25V |
54 |
0 to 0.01V |
62 |
|||
±0.625V |
5 |
±0.125V |
13 |
0 to 1V |
55 |
0 to 20mA |
100 |
|||
±0.5V |
6 |
±0.01V |
14 |
0 to 0.5V |
56 |
4 to 20mA |
101 |
|||
±0.3125V |
7 |
0 to 0.25V |
57 |
1 to 5V |
150 |
*About the available range,please refer to
the manual of the using board
*In the initial state and if terminal is not connected, the initial setting
value depends on the device
Please refer to [Device-specific
Setting List]
AiChannelNum |
[-1] Can be set |
Initial value: 1 |
In the case of analog input with buffer,
specify the number of channels for sampling
The channels to be used are[Ch0 to Ch(AiChannelNum-1)]
e.g.) When AiChannelNum is 3, the 3 channels (Ch0, Ch1, Ch2) are used in order
*In the case of analog input without buffer,
this setting is ignored, so no need to set this terminal
*Some devices may not use [Ch0, Ch1, Ch2, ...], any channel can be used
Please refer to the advanced function [AioSetAiChannelSequence_i.vi]
AiInputMethod |
[-1] Can be set |
Initial value: -1(Not change) |
Specify the connection type of analog input (Single-end/Differential)
0:
Single-end input
1: Differential input
*About the available connection type, please
refer to the manual of the using board
*In the initial state and if terminal is not connected, for the device
which supports differential input only, the initial setting value is 1
(Differential input),
For the other devices, the initial setting value is 0 (Single-end input)
There is an initial value for each input terminal setting. For example, since the initial value of [AiChannelNum] that specifies the number of channels of analog continuous input is [1], there is no particular need to set [AiChannelNum] when sampling 1 channel.
|