SmcWGetDigitalOut


Function

Retrieves the data of general purpose output signal.

Format

Ret = SmcWGetDigitalOut( Id, AxisNo, OutData )

Parameters

Id [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
SSpecify the Deice ID retrieved by SmcWInit function.

AxisNo [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify the axis number.

OutData [ VB.NET: Short ] [ C, C++: short *] [ C#: out short ] [ Python: ctypes.POINTER(ctypes.c_short) ]
Specify the address of a variable to store the data of general purpose output signal.

[ 0 | 0 | 0 | 0 | 0 | OUT3 | OUT2 | OUT1 ]

0

Signal OFF

1

Signal ON

Return Value

Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]

0

Terminated normally

Non-zero

Terminated abnormally

See also: Error code details

Remarks

This function can be executed even if the axis is in operation.

Example

The general-purpose output signal data of axis number 1 is acquired.

VB.NET
Dim Ret As Integer
Dim OutData As Short
Ret = SmcWGetDigitalOut( Id , 1, OutData )

C, C++
long Ret;
short OutData;
Ret = SmcWGetDigitalOut( Id , 1, &OutData );

C#
int Ret;
short OutData;
Ret = Smc.WGetDigitalOut( Id , 1, out OutData );

Python
Ret = ctypes.c_long()
OutData = ctypes.c_short()
Ret.value = csmc.SmcWGetDigitalOut( Id , 1, ctypes.byref(OutData) )

See Also

SmcWSetDigitalOut