Example procedure for changing network settings for CPSN-MCB271

When configuring the network settings for CPSN-MCB271 (changing the IP address, etc.), the device name set on the I/O module also needs to be reconfigured.
Please refer to the following steps.

 

1. Change the IP Address of CPSN-MCB271-1-081. (For example, 10.1.1.101 -> 10.1.1.106)
    Click on the "Save" button.

 

2. A new CPSN-MCB271 (IP Address 10.1.1.106) will be added and registered under the "NET" tree as an icon.
    The newly added I/O module will be in "(New) Model" state and will be an icon.

    The old CPSN-MCB271 (IP Address 10.1.1.101) under the "NET" tree is determined to be not connected to the network and becomes an icon.
    The I/O module under the old CPSN-MCB271 also becomes an icon.

 

3. Please set the device name for the newly added I/O module under CPSN-MCB271 "(New) Model".

    Note that the same device name cannot be set for different devices.
    If you set a device name that has already been set, the message [The device of "Device Name" is invalid] will be displayed. ("AIO000" or "DIO000")

 

[Supplement]

  If you want to register the same device name to the newly added I/O module "(New) Model" under CPSN-MCB271, follow the procedure below.

    1. Please delete the old CPSN-MCB271 which is recognized as not connected.
    2. Please set a device name for the newly added I/O module "(New) Model" under CPSN-MCB271.