There are several possible causes.
1."XXX-NET-TYPE1" has not been manually installed.
Please perform "Add legacy hardware"
from Device Manager.
For details, please refer to the device manual.
<Example of message when DIO-NET-TYPE1
or AIO-NET-TYPE1 is not registered>
2.The network environment does not support multicast communication.
CONTEC Device Utility uses multicast communication
to detect Ethernet devices.
Normally, you can use it without changing the IP address of the PC, but
multicast communication may not be possible depending on the network environment.
Please try the following actions.
- Change the IP address of the PC to the
same network layer as the IP address of the device.
Example: If the IP address of the device is [192.168.0.1],
set the IP address of the PC to [192.168.0.100].
- Try specifying the IP address of the device
using the "Manual detect" button.
Please refer to the device manual for IP address initial value
etc. of the Ethernet device.