Inputs multiple bits from input ports on the wireless I/O device.
Ret = DioInpMultiBitSR ( Id , BitNo , BitNum , Data , Timestamp , Mode )
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the device ID retrieved from DioInit.
BitNo [
VB.NET: Short ] [ C, C++: short * ] [ C#: out short ] [ Python: ctypes.POINTER(ctypes.c_short)
]
Store the logical input bit numbers into an array, and specify the base
address of this array.
BitNum [
VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the number of bits which are specified by BitNo. The maximum number
of bits is 256.
Data [
VB.NET: Byte ] [ C, C++: BYTE * ] [ C#: out byte ] [ Python: ctypes.POINTER(ctypes.c_ubyte)
]
Specify the base address of the array to store the input data.
Timestamp
[ VB.NET: UShort ] [ C, C++: unsigned short * ] [ C#: out ushort
] [ Python: ctypes.POINTER(ctypes.c_ushort) ]
Specify the address of the variable to store the timestamp.
Mode [
VB.NET: Byte ] [ C, C++: BYTE ] [ C#: out byte ] [ Python: ctypes.c_ubyte
]
Specify where to refer to the input data.
Definition |
Value [Dec] |
Description |
DIONET_MODE_DIRECT |
0 |
Refer to the input data of Terminal. |
DIONET_MODE_AP |
1 |
Refer to the input data of Gateway. |
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
Definition |
Value [Dec] |
Description |
DIO_ERR_SUCCESS |
0 |
Normal completed. |
DIO_ERR_SYS_RECOVERED_FROM_STANDBY |
7 |
Execute DioResetDevice function because the device has recovered from standby mode. |
DIO_ERR_DLL_INVALID_ID |
10001 |
Invalid ID specified. |
DIO_ERR_DLL_CALL_DRIVER |
10002 |
Not call the driver (Failure on DEVICE I/O CONTROL). |
DIO_ERR_DLL_BUFF_ADDRESS |
10100 |
Invalid data buffer address. |
DIO_ERR_SYS_NOT_SUPPORTED |
20001 |
This board couldn't use this function. |
DIO_ERR_SYS_BIT_NO |
20102 |
Bit No. beyond the limit. |
DIO_ERR_SYS_BIT_NUM |
20103 |
Bit number beyond the limit. |
The others (See also: Details of Error Code)
The initial values of input data are 0 in the state that other external equipment is not connected.
Inputs multiple bits from input ports. Before
this function is called, it is necessary that the logical bit numbers
to be input are set into the array specified by BitNo. The input data
are stored into the array named Data by the order of logical bits which
are specified by BitNo.
To acquire data, there are two methods. One is acquiring data stored in
master unit, the other one is acquiring data directly from slave unit.
Please refer to the wireless
I/O specification for features of each acquisition method.
For the data acquisition method, when acquiring
the data stored in the master unit, you can acquire the time stamp of
the data stored in the master unit.
The time stamp returns the time since the last update in seconds.
If the time stamp is longer than the update interval of the slave unit,
the data from the slave unit is not reaching the master unit for some
reason.
Please use it to check the validity of the data saved in the master unit.
Inputs data from bit 0 and bit 1.
VB.NET |
Dim Ret As Integer |
C, C++ |
long Ret; |
C# |
int Ret; |
Python |
Ret = ctypes.c_long() |
DioInpByteSR DioInpBitSR DioInpMultiByteSR