Retrieves the timing of external clock input.
Ret = AioGetAiClockEdge ( Id , AiClockEdge )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short ]
Specifies the ID retrieved from AioInit function.
AiClockEdge
[ VB.NET : Short ] [ C, C++ : short * ] [ C# : out short ] [ Python : ctypes.POINTER(ctypes.c_short) ]
Specifies the address of the variable that stores the timing of external input.
0 |
External input falling edge |
1 |
External input rising edge |
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
12320 |
Pointer
to AiClockEdge is NULL |
20001 |
This function can't be used by this device |
20002 |
Can
not use while by another device works |
20003 |
Can
not use because another process is using the device |
External input falling edge is used for all devices. *
* In case of using ADA16-8/2(LPCI)L and AD16-16(LPCI)L
For these devices, the default value has both parameters (rising or falling),
it depends on manufacturer's serial version.
This function cannot be used on devices without
the analog input function.
If the device is in operation, the function cannot be performed.
DEMO DEVICE do not support external clock function.