AioGetAiClockType


Function

Retrieves the clock type.

Format

Ret = AioGetAiClockType ( Id , AiClockType )

Parameters

Id [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short ]
Specifies the ID retrieved from AioInit function.

AiClockType [ VB.NET : Short ] [ C, C++ : short * ] [ C# : out short ] [ Python : ctypes.POINTER(ctypes.c_short) ]
Specifies the address of the variable that stores the clock type.

0

Internal clock

1

External clock

10

Event controller output

Return value

Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]

Return values

Content

0

Normality completion

7

Execute AioResetDevice function because the device has recovered from standby mode

10001

Invalid Id was specified
Use the Id retrieved from AioInit to specify the Id in this function.

10002

AIO driver can't be called
At first, perform AioInit function.

11130

Pointer to AiClockType is NULL
Specify the address of variable to parameter.

20001

This function can't be used by this device

20002

Can not use while by another device works
To use this function, analog input operation must be stopped.

20003

Can not use because another process is using the device
When another process is using the device, all functions except for those that support multi-process can not be performed.

Initial value

Internal clock is used for all devices.

Remarks

This function cannot be used on devices without the analog input function.
If the device is in operation, the function cannot be performed.

Example

Retrieves the clock type.

VB.NET

Dim Ret As Integer
Dim AiClockType As Short
Ret = AioGetAiClockType ( Id , AiClockType )
 

C, C++

long Ret;
short AiClockType;
Ret = AioGetAiClockType ( Id , &AiClockType );
 

C#

int Ret;
short AiClockType;
Ret = aio.GetAiClockType ( Id , out AiClockType );
 

Python

Ret = ctypes.c_long()
AiClockType = ctypes.c_short()
Ret.value = caio.AioGetAiClockType ( Id , ctypes.byref(AiClockType) )
 

See also

AioSetAiClockType