-Use function
Initialization function( SmcWSetPulseType SmcWSetSAccelType SmcWSetEncType )
-Outline
Set the pulse output mode and encoder input type.
-Operation method
• PulseType(The pulse output mode is set.) SmcWSetPulseType function
Common pulse method OUT: Negative logic, DIR+: High, DIR-: Low
Common pulse method OUT: Positive logic, DIR+: High, DIR-: Low
Common pulse method OUT: Negative logic, DIR+: Low, DIR-: High
Common pulse method OUT: Positive logic, DIR+: Low, DIR-: High
2-pulse mode: Negative logic
2-pulse mode: Positive logic
Phase difference mode of 90 degrees OUT:Leading,DIR:Trailing
Phase difference mode of 90 degrees OUT:Trailing,DIR:Leading
• Reverse Direction Timer (SmcWSetPulseType function)
The weight (delay) at 200 microseconds is inserted before the pulse is output when the direction changes by the change in the DIR change when the common pulse method is set.(It is effective only for the common pulse method. )
• S Accel/Decel Use (Set whether to use S speed.) SmcWSetSAccelType function
• Encoder Type(encoder type) SmcWSetEncType function
A/B two-phase input 1 times
A/B two-phase input 2 times
A/B two-phase input 4 times
U/D single-phase input 1 times
• To apply the settings to the device, click [q:Back] to return to the initial setting menu and execute [2:Set].