ERC/ALM Clear Setting

-Use function

 Initialization function ( SmcWSetErcAlmClearTime SmcWSetErcMode )

 

-Outline

The width etc. of a clear signal are set by using the initialization function.

 

-Operation method

• Counter Clear(ERC)

Stop by LIM and ALM input

0 : When stopping by LIM and the ALM signal input, the ERC signal is not output.

1 : When stopping by LIM and the ALM signal input, the ERC signal is output.

ORG motion end

0: When the starting point resume operation is completed, the ERC signal is not output.

1: When the starting point resume operation is completed, the ERC signal is output.

 

• Counter Clear Time(The width of a deflection counter clear signal is set. )

12[usec]

102[usec]

408[usec]

1.6[msec]

13[msec]

52[msec]

104[msec]

Level output

 

• Counter Off Timer(The time of deflection counter clear signal OFF timer is set. )

0[usec]

12[usec]

1.6[msec]

104[msec]

 

• Alarm Clear Time(The width of an alarm clear signal is set. )

12[usec]

102[usec]

408[usec]

1.6[msec]

13[msec]

52[msec]

104[msec]

 

• To apply the settings to the device, click [q:Back] to return to the initial setting menu and execute [2:Set].