Status Window


This window shows the operating status of the device.

Item

Pattern

Description

Operation status

Run

Data is being transferred

Wait for start trigger

After the operation starts, it is waiting for the start by an external trigger.

Stop

Stopped

Transfer mode

Generating

Set to generating mode.

Sampling

Set to sampling mode.

Current position

Current number of clocks / total [Clock]

Displayed in this format when the specified number of transfers is specified in the stop condition.

Current number of clocks [Clock][Clock]

Displayed in this format when a stop condition other than the specified number of transfers is specified.

Repeat times

Number of repetitions [times]

Displayed when generation repeat times is specified.

Error

Bus master transfer error

The bus master transfer was not in time. Please lower the transfer rate.

External start trigger and stop trigger input at the same time error

Indicates that the start signal and stop signal are input at the same time with an external start. Check how the external start signal and external stop signal are input.

External clock error

Indicates that the next clock has entered during data entry with an external clock. If this status is set, it will not operate at the specified external clock. Consider lowering the cycle of the external clock.

File write error

File writing was not in time.