Reference

It is dependent on the device to be used and the performance of PC whether a high-speed and long-time acquisition can be materialized.

In this chapter, a measurement is performed whether the infinite sampling can be materialized at some conditions.
The values described in each table are the maximum standard value of sampling clock
period that can be specified.

For automatic saving to a text file, reducing the memory size used by the C-LOGGER may increase the upper limit of the configurable sampling clock period.

 

Common Condition

- Operating System : Windows 10 20H2 64bit
- Number of Channel : 1 channel
- Sampling Times : Infinity
- Only 1 YT Window is shown during acquisition

 

Measurement Result

Used Device : AI-1204Z-PCI

Acquisition Conditions

PC : Core i7-8700 3.20GHz, 32GB Memory

Memory size : 10×1,000,000 [WORD]

PC : Core i7-8700 3.20GHz, 32GB Memory

Memory size : 1×1,000,000 [WORD]

Save to binary file automatically

Max. 0.2µsec

Max. 0.2µsec

Save to text file automatically

Max. 35µsec

Max. 4µsec

 

Used Device : AIO-163202F-PE

Acquisition Conditions

PC : Core i7-8700 3.20GHz, 32GB Memory

Memory size : 10×1,000,000 [WORD]

PC : Core i5-6500 3.20GHz, 8GB Memory

Memory size : 1×1,000,000 [WORD]

Save to binary file automatically

Max. 2µsec

Max. 2µsec

Save to text file automatically

Max. 65µsec

Max. 8µsec

 

利用デバイス: AIO-160802L-LPE

Acquisition Conditions

PC : Core i7-8700 3.20GHz, 32GB Memory

Memory size : 10×1,000,000 [WORD]

PC : Core i5-6500 3.20GHz, 8GB Memory

Memory size : 1×1,000,000 [WORD]

Save to binary file automatically

Max. 10µsec

Max. 10µsec

Save to text file automatically

Max. 120µsec

Max. 15µsec