Sync Setting
① DIO Device [sync_dio.vi]

 

Select when setting synchronous operation on a digital device

 

 


IN/OUT Terminal layout

 


Input terminal

SyncMode

Initial value: 0 (StandAlone)

[Essential]
Select synchronous mode

    0: StandAlone
    1: Master
    2: Slave

- Stand-alone
Specify this when using the device alone or without using it in sync with other devices

- Master
Specify this when performing synchronous operation with the target board as the master

- Slave
Specify this when performing synchronous operation with the target board as a slave

 

ExtSignal1

Initial value: 0

ExtSignal2

Initial value: 0

ExtSignal3

Initial value: 0

When using with master or slave, set synchronization control signal
No need to specify for Stand-alone

- In case of master

Specify the signal to be output to the three terminals (ExtSignals 1 to 3) of the synchronous control connector

Value

Output signal

0

Not Used

Sampling (Digital input) signal

1

Software start (Pattern input)

2

Software stop (Pattern input)

3

Internal clock (Pattern input)

4

External clock (Pattern input)

5

Rising edge of external start trigger (Pattern input)

6

Falling edge of external start trigger (Pattern input)

7

Pattern matching (Pattern input)

8

Rising edge of external stop trigger (Pattern input)

9

Falling edge of external stop trigger (Pattern input)

10

Clock error (Pattern input)

11

Handshake (Pattern input)

Generating (Digital output) signal

101

Software start (Pattern output)

102

Software stop (Pattern output)

103

Internal clock (Pattern output)

104

External clock (Pattern output)

105

Rising edge of external start trigger (Pattern output)

106

Falling edge of external start trigger (Pattern output)

107

Rising edge of external stop trigger (Pattern output)

108

Falling edge of external stop trigger (Pattern output)

109

Clock error (Pattern output)

110

Handshake (Pattern output)

About signal assignment to synchronous control connector

Which signal is assigned to each of the three terminals of the synchronous control connector is arbitrary by the user,

but we recommend the following assignment as standard and recommended.

Synchronous Control Signal 1 (ExtSignal1): Clock signal
Synchronous Control Signal 2 (ExtSignal2): Start signal
Synchronous Control Signal 3 (ExtSignal3): Stop signal

 

- In case of slave

Specify whether to use each Synchronous Control Signal (ExtSignal 1 to 3)

Value

Use or not

0

Invalid

1

Valid