Select when setting synchronous operation on a digital device
SyncMode |
Initial value: 0 (StandAlone) |
[Essential]
Select synchronous mode
0:
StandAlone
1: Master
2: Slave
- Stand-alone
Specify this when using the device alone or without using it in sync with
other devices
- Master
Specify this when performing synchronous operation with the target board
as the master
- Slave
Specify this when performing synchronous operation with the target board
as a slave
ExtSignal1 |
Initial value: 0 |
ExtSignal2 |
Initial value: 0 |
ExtSignal3 |
Initial value: 0 |
When using with master or slave, set synchronization
control signal
No need to specify for Stand-alone
- In case of master
Specify the signal to be output to the three terminals (ExtSignals 1 to 3) of the synchronous control connector
Value |
Output signal |
0 |
Not Used |
Sampling (Digital input) signal |
|
1 |
Software start (Pattern input) |
2 |
Software stop (Pattern input) |
3 |
Internal clock (Pattern input) |
4 |
External clock (Pattern input) |
5 |
Rising edge of external start trigger (Pattern input) |
6 |
Falling edge of external start trigger (Pattern input) |
7 |
Pattern matching (Pattern input) |
8 |
Rising edge of external stop trigger (Pattern input) |
9 |
Falling edge of external stop trigger (Pattern input) |
10 |
Clock error (Pattern input) |
11 |
Handshake (Pattern input) |
Generating (Digital output) signal |
|
101 |
Software start (Pattern output) |
102 |
Software stop (Pattern output) |
103 |
Internal clock (Pattern output) |
104 |
External clock (Pattern output) |
105 |
Rising edge of external start trigger (Pattern output) |
106 |
Falling edge of external start trigger (Pattern output) |
107 |
Rising edge of external stop trigger (Pattern output) |
108 |
Falling edge of external stop trigger (Pattern output) |
109 |
Clock error (Pattern output) |
110 |
Handshake (Pattern output) |
Which signal is assigned to each of the three terminals of the synchronous control connector is arbitrary by the user, but we recommend the following assignment as standard and recommended. Synchronous
Control Signal 1 (ExtSignal1): Clock signal
|
- In case of slave
Specify whether to use each Synchronous Control Signal (ExtSignal 1 to 3)
Value |
Use or not |
0 |
Invalid |
1 |
Valid |