Read
① Digital Input (1bit) [read_di_1ch1bit.vi]

 

Select when digital input 1 bit

It is also possible to perform digital input of analog devices and counter devices

 


Layout of IN/OUT terminal

 


IN terminal

DiBit

Initial value: 0

[Essential]
Specify the bit No. to perform digital input

*In case of counter device, please specify the channel number for digital input

 

Mode

Initial value: 0

Normally not connected or specified as 0
The following settings are available only for wireless I/O devices

0: Refers to the input data of the slave stored in the Gatway
1: Directly access the Terminal and refer to the input data
2: Refer to the input data of the Terminal stored in the Gatway and the elapsed time (ElapsedTime)

 

OUT terminal

DiData

Get the digital input data

 

ElapsedTime

Gets the elapsed time (seconds) after data is stored in the Gatway when Mode=2 is set in the wireless I/O device