AiScanClock


Function

 

Sets or gets the scan clock in usec units.

 

Variable type

 

[ C#: float ] [ VB.NET: Single ]

 

Initial value

 

It depends on the device.

 

Setting value

 

The values that can be set depend on the device.

 

Remarks

 

Sets or gets the scan clock.

The scan clock that can be set depends on the conversion speed.
The property change will be reflected on the device at the time of Init of DncDaq.

 

Device-specific specifications

Device

Description

AIO-123202G-PE
AIO-163202G-PE

Usable AiScanClock is 10 to 1638(Unit: usec).
Initial value is AiScanClock = 10.

AI-1664UG-PE

AIO-123202UG-PE
AIO-163202UG-PE

Usable AiScanClock is 1 to 1638(Unit: usec).
Initial value is AiScanClock = 1.

AIO-163202F-PE
ADA16-32/2(PCI)F

Usable AiScanClock is 2 to 1638(Unit: usec).
Initial value is AiScanClock = 2.

AD12-16(PCI)E
AD12-16(PCI)EV
AD16-16(PCI)E
AD16-16(PCI)EV
AIO-121601E3-PE
AIO-161601E3-PE

Usable AiScanClock is 10 to 1638.
Initial value is AiScanClock = 10.

AD12-16U(PCI)E
AD12-16U(PCI)EH
AD12-16U(PCI)EV
AD16-16U(PCI)EH
AD16-16U(PCI)EV
AIO-121601UE3-PE
AIO-161601UE3-PE

Usable AiScanClock is 1 to 1638.
Initial value is AiScanClock = 1.

AIO-163202FX-USB

Usable AiScanClock is 2 to 1638(Unit: usec).
Initial value is AiScanClock = 2.

DEMO DEVICE

Usable AiScanClock is 1 to 0xffffffff.
Initial value is AiScanClock = 1.