If Init process fails at the DncDaq startup, the property screen will be displayed again by default.
*When InitNGMode is PropertyPage/Auto
The following cases are possible when the setting is required again, so please reconfigure and build the application again.
■When the setting device does not exist
If the setting device name does not exist in the Device settings and Input Task/Output Task settings, the Init process will fail.
In that case, please set the device again according to the following procedure.
①Select a new device in the Device settings
②Select a new device in the Input Task
If the device does not
exist, the following error message will be displayed.
Check the device for each task and set it again.
③Select a new device in the Output Task
As with the Input Task, if the device does not exist, an error message will be displayed.
Check the device for each task and set it again.
■When the settings and the functions that can be used on the device are different
For example, if the digital filter function is set and the actual device cannot be used, the Init process will fail.
In that case, check various settings on the device setting screen and set the available settings again.