In/Out Setting


Overview

The I/O of the output three points and the input seven points is set.

Use function

Initialization function( SmcWSetCtrlTypeOut SmcWSetCtrlTypeIn SmcWSetInFilterType SmcWSetSDMode )

Step to Use

- OUT Setting. SmcWSetCtrlTypeOut function

General-Purpose Output Signal
Alarm Clear Signal
Error Counter Clear Signal (ERC)
OutPulse Count Match(CP1)
Encoder Count Match(CP2)
Hold-Off Signal

- IN Setting. SmcWSetCtrlTypeIn function

General-Purpose Input Signal
ALM(Alarm)
INP(Servo driver's positioning completion signal input)
SD(Slow down)
LTC(The latch does COUNTER1-2.)
PCS(The positioning operation of this signal input begins.)
CLR(Counter clear)

- In Filter Setting (LIM, SD, ORG, ALM, INP, The input filter is set.). SmcWSetInFilterType function

Not Use
Disregard 3.2 [µsec] or less
Disregard 25 [µsec] or less
Disregard 200 [µsec] or less
Disregard 1.6 [msec] or less

- SD Mode Setting(Slow down mode). SmcWSetSDMode function

Slow Down & Stop
Slow Down(to beginning speed)