Function
Retrieves the beginning speed of bank/interpolation operation.
Format
Ret = SmcWGetBankStartSpeed( Id , AxisNo , BankNo , StartSpeed )
Parameters
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
SSpecify the Deice ID retrieved by SmcWInit function.
AxisNo
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify axis number.
BankNo
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify bank number.
StartSpeed
[ VB.NET: Double ] [ C, C++: double ] [ C#: double ] [ Python: ctypes.c_double
]
The address of the variable that stores the beginning speed is specified.
The unit is PPS.
Return Value
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
0 |
Terminated normally |
Non-zero |
Terminated abnormally |
See also: Error code details
Remarks
SMC-2/4/8DL series is "BankNum=1" fixation.
The value is corrected to the multiple of
the resolution set with SmcWSetBankResolveSpeed.
Example: 105pps in case of 15pps Resolution.
This function can be executed even if the axis is in operation.