SmcWGetBankStartSpeed


Function

Retrieves the beginning speed of bank/interpolation operation.

Format

Ret = SmcWGetBankStartSpeed( Id , AxisNo , BankNo , StartSpeed )

Parameters

Id [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
SSpecify the Deice ID retrieved by SmcWInit function.

AxisNo [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify axis number.

BankNo [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify bank number.

StartSpeed [ VB.NET: Double ] [ C, C++: double ] [ C#: double ] [ Python: ctypes.c_double ]
The address of the variable that stores the beginning speed is specified. The unit is PPS.

Return Value

Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]

0

Terminated normally

Non-zero

Terminated abnormally

See also: Error code details

Remarks

SMC-2/4/8DL series is "BankNum=1" fixation.

The value is corrected to the multiple of the resolution set with SmcWSetBankResolveSpeed.
Example: 105pps in case of 15pps Resolution.

This function can be executed even if the axis is in operation.

See Also

SmcWSetBankStartSpeed