Function
Sets output mode of pulse.
Format
Ret = SmcWSetPulseType( Id, AxisNo, PulseMode, DirTimer )
Parameters
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
SSpecify the Deice ID retrieved by SmcWInit
function.
AxisNo
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the axis number.
PulseMode
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Set pulse output mode.
Pulse mode |
(+)direction operates |
(-)direction operates |
||
|
OUT output |
DIR output |
OUT output |
DIR output |
0 |
||||
Common pulse mode OUT:Negative logic, CDIR+:High, CDIR-:Low |
||||
1 |
||||
Common pulse mode OUT:Positive logic, CDIR+:High, CDIR-:Low |
||||
2 |
||||
Common pulse mode OUT:Negative logic, CDIR+:Low, CDIR-:High |
||||
3 |
||||
Common pulse mode OUT:Positive logic, CDIR+:Low, CDIR-:High |
||||
4 |
||||
2-pulse mode :Negative logic |
||||
5 |
||||
2-pulse mode :Positive logic |
||||
6 |
||||
Phase difference mode OUT of 90 degrees: It is willingly signal. DIR: Delay signal |
||||
7 |
||||
Phase difference mode OUT of 90 degrees: Delay signal. DIR: It is willingly a signal |
DirTimer
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
If the common pulse method is being set, when the direction changes depending
on the change of DIR change, insert 200[u sec] wait (delay) before the
pulse output. (Only used in the case of common pulse method)
0 |
OFF |
1 |
ON |
Return Value
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
0 |
Terminated normally |
Non-zero |
Terminated abnormally |
See also: Error code details
Initial Value
PulseMode |
4 : 2 pulses mode :Negative logic |
DirTimer |
1 : ON |
Remarks
This function cannot be executed when the device is in operation.
After "Initial Setting function"
is executed, it is necessary to execute SmcWSetInitParam.
Refer to "About Initial
Setting function".
Example
The pulse output mode of axis number 1 is
set.
It is common pulse method OUT as for the output mode of the pulse: The
positive logic, DIR+:High, and DIR-:Low.
The weight (delay) at 200 microseconds is inserted before the pulse is
output when the direction changes by the change in the DIR change when
the common pulse method is set.
VB.NET
Dim Ret As Integer
Dim PulseMode As Short
Dim DirTimer As Short
PulseMode = 1
DirTimer = 1
Ret = SmcWSetPulseType( Id , 1, PulseMode , DirTimer )
C, C++
long Ret;
short PulseMode ;
short DirTimer ;
PulseMode = 1;
DirTimer = 1;
Ret = SmcWSetPulseType( Id , 1, PulseMode , DirTimer );
C#
int Ret;
short PulseMode ;
short DirTimer ;
PulseMode = 1;
DirTimer = 1;
Ret = Smc.WSetPulseType( Id , 1, PulseMode , DirTimer );
Python
Ret = ctypes.c_long()
PulseMode = ctypes.c_short()
DirTimer = ctypes.c_short()
PulseMode.value = 1
DirTimer.value = 1
Ret.value = csmc.SmcWSetPulseType( Id , 1, PulseMode , DirTimer )