Network Setting
1. After USB connecting your PC and this device, start the CONTEC Device Utility.
2. When this device is detected by USB connection, "DIO-0404LY-WQ-CN" is displayed in the "Setting mode" tree.
3. Set the following "Setting item" on the "Setting"
tab.
To make advanced settings, also make settings on the
"Advanced" tab.
4. Click "Save" button.
While the setting is being written, the LED on the unit
flashes.
When the LED turns on, the target device will automatically
reboot and the settings will be applied.
The setting itself has been completed so far.
5. Please detect the device again and confirm that the setting contents are applied.
6. If you want to change the setting contents, please click "Save" again after changing.
[Device information area] Display information of the selected device
Device Type |
Display device type |
Device |
Display product model |
Serial number |
Display the serial number of the product |
RSSI |
It
displays the signal strength of 920 MHz band communication with
its own master unit GW1-ETH-WQ-CN. We recommend the signal strength keeps more than -70dB. |
[Setting item] You can set the selected device
"Setting" tab |
|
Device ID |
When using several slave units with one GW1-ETH-WQ-CN, it is necessary to set the Device ID uniquely. [When the product's rotary switch is other than F] The value of the rotary switch is displayed. You can not change here. [When the product's rotary switch is F] Set the Device ID here. Settable range: 0 to 127 |
PAN ID |
Set the PAN ID used for wireless communication. Settable range: 0 to 32767 |
Data Interval |
Sets the time interval at which the digital input value of this device is transmitted to its master unit GW1-ETH-WQ-CN. Settable range: 10 to 3600 (sec) |
Click the "Advanced" button to display the advanced settings dialog.
"Advanced settings" dialog |
|
Device Mode |
Select
from the following two modes. - Wireless I/O mode This is the standard mode. Select this mode when using this device with API-DIO(WDM) driver. - Peer to Peer mode Select when using two products as a pair without using the master unit. It is necessary to set the Device ID of the paired
device. |
"Common Setting" |
|
Tx Power |
Set transmission output. Normally, it uses the initial value of 5 (mW). |
Bit Rate |
Set the bit rate (communication speed). Normally, it uses the initial value of 80 (kbps). |
Request Timeout |
Set the communication timeout time between the master unit and slave unit. The initial value is 3000. Settable range: 1000 to 60000 (msec) |
Aging Time |
Set the connection maintenance time between the master and slave. The initial value is 600. Normally, use the default value, but if you have changed Data Interval setting, We recommend changing the value to about 10 times Data Interval setting. Also, when changing this setting, it is recommended to set the same setting for the master unit. Settable range: 60 to 36000 (sec) |
Encryption Key |
Set the encryption key used for communication between the master unit and the slave unit. It is specified with 32 digit hexadecimal number, and the initial value is all 0. In order for the master unit and the slave unit to communicate, the same value must be set in Encryption Key. |
Digital Filter |
Set the digital filter value at power on of this device. The initial value is Disabled. When using this device with API-DIO(WDM) driver, it is possible to set the digital filter at any time by API function separately from this setting. |
"Wireless I/O
mode Setting" |
|
DI Count |
Select Enabled if you want the digital input counting function to start when the device starts up. Apart from this setting, it is also possible to start and stop by executing the API function after starts up. In addition, Digital Filter must be enabled to use this function. |
Count Edge |
Select the direction for counting digital inputs. - When Rising is selected, the rising edge (0->1) of digital input signal is counted. - When Falling is selected, the falling edge (1->0) of the digital input signal is counted. - When Both is selected, both rising (0->1) and falling (1->0) of the digital input signal are counted. |
"Peer-to-Peer
mode Setting" |
|
Pair Device ID |
Set the Device ID of the device paired with this device. |
Device Name Setting
1. Configure the network of GW1-ETH-WQ-CN which will be the master unit
of this device in advance.
If the LED of this device is on in orange, wireless communication
with GW1-ETH-WQ-CN is established.
2. After LAN connecting your PC and GW1-ETH-WQ-CN, start the CONTEC Device Utility.
3. When this device is newly detected via GW1-ETH-WQ-CN, "(New)
DIO-0404LY-WQ-CN" will be displayed
under "GW1-ETH-WQ-CN" in the "NET"
tree, and the temporary device name is displayed in the light yellow
"Device Name".
4. Specify the device name in the "Device Name" and click
the "Save" button.
The setting of the device name itself has been completed
so far.
5. The configured device is indicated as "[device name] DIO-0404LY-WQ-CN", and the device name is displayed in the white "Device Name".
6. If you select this configured device, the "Diagnosis" button will be enabled.
Clicking this button will start the diagnostic program
and check the operation.
In addition, it is possible to simply display the operating
status with the "Status" button.
7. If you want to change the setting contents, please click "Save" again after changing.
* You can see the status of Hop Route information when you use Hop feature.
It is displayed "Directly connected to Gateway" on Hop
Route Info item when you connect to GW1-ETH-WQ(Master Unit) directly
like above.
* When the Device Name is set, the fail-safe activation state is displayed.
If fail-safe is activated, you can reset by Reset status button.
Fail-Safe Setting
Fail-Safe feature is available when you configure wireless I/O mode on your device.
1. After LAN connecting your PC and this device, start the CONTEC Device Utility.
2. Set the following "Setting item"
on the "FailSafe" tab.
To output multiple data with fail-safe, check "Output
Multi Data" and make settings on the "FailSafe(MultiData)"
tab as well.
3. Click the "Save" button.
While the setting is being written, the LED on the unit
flashes.
When the LED turns on, the target device will automatically
reboot and the settings will be applied.
See also "FailSafe Setting" for details on the fail-safe function.
[Setting item] You can set the selected device
"FailSafe" tab |
|
Event Trigger - Linkdown |
Select this when activating fail-safe when link down state occurs, such as when the LAN cable is disconnected. |
Event Trigger - No Access |
Select this when activating fail-safe when there is no access for the set time. Settable range: 1 to 3600 (sec) |
Start wait time |
Set the time to disable the fail-safe function after turning on the power. The fail-safe function is enabled after the set time has elapsed. Settable range: 0 to 3600 (sec) |
FailSafe OutBit (Hex) |
Set the output terminal to output with the fail-safe function. Set the output terminal in hexadecimal. Settable range: 0 to F Setting example: To use output terminals 0, 1, 2, 3, set F |
Output Data (Hex) |
Set the output data to be output with the fail-safe function. Set 0 or 1 output in hexadecimal from the output terminal set with "FailSafe OutBit (Hex)". Settable range: 0 to F Setting example: To set the output of output terminals 0, 1, 2, 3 to "0, 1, 0, 1", set A |
Output Multi Data |
Check this if you want to output multiple data continuously when fail-safe is activated. When checked, the "FailSafe(MultiData)" tab will appear, so set up multiple data there. |
"FailSafe(MultiData)" tab |
|
Output Data (Hex) 1`8 |
Up to eight fail-safe output data can be set. The setting method is the same as above "Output Data (Hex)". |
Hold Time (*100msec) 1`8 |
Set the data output time in units of 100 milliseconds. After this time, the next data is output. Settable range: 1 to 600 (*100msec) |
patterns |
Set the number of data to be output. |
Repeat |
After outputting the number of data set with "patterns", set whether to repeat output from 1 of "Output Data" again. If you do not repeat, select "1 time". To repeat infinitely, select "Infinite". It can also be repeated a certain number of times, the setting range is 2 to 255 times. |
Firmware Update
1. After USB connecting your PC and this device, start the CONTEC Device Utility.
2. When this device is detected by USB connection, "DIO-0404LY-WQ-CN" is displayed in the "Setting mode" tree.
3. When you select a device and click the "Firmware" tab, "Current version" shows the current firmware version.
4. When clicking "Write new firmware", a file selection dialog
is displayed.
Please select the firmware file to be written.
5. While the firmware is being written, the LED on the unit flashes.
When the LED turns on, the target device will automatically
reboot and the new firmware will be applied.
The firmware update itself has been completed so far.
6. Please detect the device again and confirm that the version of "Current version" has been updated.