Inputs multiple ports for the status of multiple output ports.
Ret = DioEchoBackMultiByte ( Id , PortNo , PortNum , Data )
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the device ID retrieved from DioInit.
PortNo [
VB.NET: Short ] [ C, C++: short * ] [ C#: out short ] [ Python: ctypes.POINTER(ctypes.c_short)
]
Store the logical output port numbers into an array, and specify the base
address of this array.
PortNum
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the number of ports which are specified by PortNo. The maximum
number of ports is 256.
Data [
VB.NET: Byte ] [ C, C++: BYTE * ] [ C#: out byte ] [ Python: ctypes.POINTER(ctypes.c_ubyte)
]
Specify the address of the variable to store the output data. The output
data are returned by hex number from 0H to FFH.
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
Definition |
Value [Dec] |
Description |
DIO_ERR_SUCCESS |
0 |
Normal completed. |
DIO_ERR_SYS_RECOVERED_FROM_STANDBY |
7 |
Execute DioResetDevice function because the device has recovered from standby mode. |
DIO_ERR_DLL_INVALID_ID |
10001 |
Invalid ID specified. |
DIO_ERR_DLL_CALL_DRIVER |
10002 |
Not call the driver (Failure on DEVICE I/O CONTROL). |
DIO_ERR_DLL_BUFF_ADDRESS |
10100 |
Invalid data buffer address. |
DIO_ERR_SYS_NOT_SUPPORTED |
20001 |
This board couldn't use this function. |
DIO_ERR_SYS_PORT_NO |
20100 |
Port No. beyond the limit. |
DIO_ERR_SYS_PORT_NUM |
20101 |
Port number beyond the limit. |
The others (See also: Details of Error Code)
The initial values of output data are 0 after the device is reset. (DIO-0808RN-USB is set to FFH)
Inputs multiple ports for the status of multiple
output ports. Before this function is called, it is necessary that the
logical port numbers to be input are set into the array specified by PortNo.
The data are stored into the array named Data by the order of logical
ports which are specified by PortNo.
The output data are returned by hex number from 0H to FFH.
This function is used for monitoring the outputting contents.
Inputs the status of output port 0 and 1.
VB.NET |
Dim Ret As Integer |
C, C++ |
long Ret; |
C# |
int Ret; |
Python |
Ret = ctypes.c_long() |