Starts the count operation.
Ret = DioStartCount ( Id , ChNo , ChNum )
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the device ID retrieved from DioInit.
ChNo [
VB.NET: Short ] [ C, C++: short * ] [ C#: out short ] [ Python: ctypes.POINTER(ctypes.c_short)
]
Specify the start address of the array that stores the channel number to
start counting.
ChNum [
VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the number of channels specified in ChNo.
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
Definition |
Value [Dec] |
Description |
DIO_ERR_SUCCESS |
0 |
Normal completed |
DIO_ERR_SYS_RECOVERED_FROM_STANDBY |
7 |
Execute DioResetDevice function because the device has recovered from standby mode |
DIO_ERR_DLL_INVALID_ID |
10001 |
Invalid ID specified. |
DIO_ERR_DLL_CALL_DRIVER |
10002 |
Not call the driver (Failure on DEVICE I/O CONTROL). |
DIO_ERR_DLL_BUFF_ADDRESS |
10100 |
Invalid data buffer address. |
DIO_ERR_SYS_NOT_SUPPORTED |
20001 |
This board couldn't use this function. |
DIO_ERR_SYS_CH_NO |
20105 |
The channel number is out of specifiable range. |
DIO_ERR_SYS_CH_NUM |
20106 |
The number of channels is out of the specifiable range. |
The others (See also: Details of Error Code)
- Starts the count of the specified channels.
Starts the count of channel 0 and channel 1.
VB.NET |
Dim Ret As Integer |
C, C++ |
long Ret; |
C# |
int Ret; |
Python |
Ret = ctypes.c_long() |