Function
Clears the count value to 0. Supports multi-processing.
Format
Ret = CntZeroClearCount ( Id , ChNo , ChNum )
Parameters
Id
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the device ID retrieved from CntInit.
ChNo
[ VB.NET: Short ] [ C, C++: short * ] [ C#: out short ] [ Python: ctypes.POINTER(ctypes.c_short)
]
Specify the base address of array storing the setting channel number.
ChNum
[ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short
]
Specify the number of channels in array ChNo.
Return Value
Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]
Definition |
Value |
Description |
CNT_ERR_SUCCESS |
0 |
Normality completion |
CNT_ERR_SYS_RECOVERED_FROM_STANDBY |
7 |
Execute the function CntResetDevice to return from the standby mode. |
CNT_ERR_DLL_INVALID_ID |
10001 |
Invalid ID was specified. |
CNT_ERR_DLL_CALL_DRIVER |
10002 |
CNT driver can't be called (Failed in the device I/O control). |
CNT_ERR_DLL_BUFF_ADDRESS |
10101 |
Invalid data buffer address. |
CNT_ERR_SYS_NOT_SUPPORTED |
20001 |
This function can't be used by this device. |
CNT_ERR_SYS_CH_NO |
20201 |
Channel number is out of range. |
CNT_ERR_SYS_CH_NUM |
20202 |
Number of channels is out of range. |
The others: (See also: Details of Error Code)
Initial Value
None
Remarks
Clears the count value of specified channel to 0. Passes the channel number in array. This function is valid before or after the counter starts.
Example
Clears the count value of channel 0 and channel 1 to 0.
VB.NET |
Dim Ret As Integer |
C, C++ |
long Ret; |
C# |
int Ret; |
Python |
Ret = ctypes.c_long() |
See Also