CntStopNotifyTimer


Function

Stops the notification of timer. Supports multi-processing.

Format

Ret = CntStopNotifyTimer ( Id )

Parameters

Id [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify the device ID retrieved from CntInit.

Return Value

Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]

Definition

Value

Description

CNT_ERR_SUCCESS

0

Normality completion

CNT_ERR_SYS_RECOVERED_FROM_STANDBY

7

Execute the function CntResetDevice to return from the standby mode.

CNT_ERR_DLL_INVALID_ID

10001

Invalid ID was specified.

CNT_ERR_DLL_CALL_DRIVER

10002

CNT driver can't be called (Failed in the device I/O control).

CNT_ERR_SYS_NOT_SUPPORTED

20001

This function can't be used by this device.

The others: (See also: Details of Error Code)

Initial Value

None

Remarks

This function stops the notification of timer made valid by the CntNotifyTimer function.
Please call the function CntNotifyTimer when the notification becomes valid again.

Example

Stops the notification of timer.

VB.NET

Dim Ret As Integer
Ret = CntStopNotifyTimer ( Id )
 

C, C++

long Ret;
Ret = CntStopNotifyTimer ( Id );
 

C#

int Ret;
Ret = cnt.StopNotifyTimer ( Id );
 

Python

Ret = ctypes.c_long()
Ret.value = ccnt.CntStopNotifyTimer ( Id )
 

See Also

CntNotifyTimer CntTimerCallbackProc