CntSetCountDirection


Function

Sets the count direction (Up-count/Down count). Supports multi-processing.

Format

Ret = CntSetCountDirection ( Id , ChNo , Dir )

Parameters

Id [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify the device ID retrieved from CntInit.

ChNo [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify the channel number for setting.

Dir [ VB.NET: Short ] [ C, C++: short ] [ C#: short ] [ Python: ctypes.c_short ]
Specify the count direction. The count direction is selected from the following Definition Value.

Definition

Value

Description

CNT_DIR_DOWN

0

Down count

CNT_DIR_UP

1

Up count

Return Value

Ret [ VB.NET: Integer ] [ C, C++: long ] [ C#: int ] [ Python: ctypes.c_long ]

Definition

Value

Description

CNT_ERR_SUCCESS

0

Normality completion

CNT_ERR_SYS_RECOVERED_FROM_STANDBY

7

Execute the function CntResetDevice to return from the standby mode.

CNT_ERR_DLL_INVALID_ID

10001

Invalid ID was specified.

CNT_ERR_DLL_CALL_DRIVER

10002

CNT driver can't be called (Failed in the device I/O control).

CNT_ERR_DLL_MODE

10100

Invalid mode setting.

CNT_ERR_SYS_BOARD_EXECUTING

20002

Cannot use while by another device works.

CNT_ERR_SYS_MODE

20100

Invalid mode setting.

CNT_ERR_SYS_CH_NO

20201

Channel number is out of range.

The others: (See also: Details of Error Code)

Initial Value

Up count

Remarks

Specifies the count direction of specified channel. This function becomes valid, when the counter is started.

Example

Sets the count direction of channel 0 to Up count.

VB.NET

Dim Ret As Integer
Ret = CntSetCountDirection ( Id , 0 , CNT_DIR_UP )
 

C, C++

long Ret;
Ret = CntSetCountDirection ( Id , 0 , CNT_DIR_UP );
 

C#

int Ret;
Ret = cnt.SetCountDirection ( Id , 0 , (short)CcntConst.CNT_DIR_UP );
 

Python

Ret = ctypes.c_long()
Ret.value = ccnt.CntSetCountDirection ( Id , 0 , ccnt.CNT_DIR_UP )
 

See Also