AioStartTmCount


Function

Starts the measurement of elapsed time.

Format

Ret = AioStartTmCount ( Id , TimerId )

Parameters

Id [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short ]
Specifies the device ID retrieved from AioInit.

TimerId [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short ]
Specifies the timer ID.

Return value

Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]

Return values

Content

0

Normality completion

7

Execute AioResetDevice function because the device has recovered from standby mode

10001

Invalid Id was specified
Use the Id retrieved from AioInit to specify the Id in this function.

10002

AIO driver can't be called
At first, perform AioInit function.

16080

The value of TimerId is outside the designated range of the function

20001

This function can't be used by this device

20002

Can not use while by another device works
To use this function, timer operation must be stopped.

20003

Can not use because another process is using the device
When another process is using the device, all functions except for those that support multi-process can not be performed.

26080

The value of TimerId is outside the designated range of the device being used

Remarks

Starts the measurement of elapsed time.
After this function is performed, the elapsed time is reset to 0 and restart time counting when the function AioStartTmCount is performed again without performing the function AioStopTmCount.

This function cannot be used on devices without timer functionality.

Example

Starts the measurement of elapsed time for timer ID 0.

VB.NET

Dim Ret As Integer
Ret = AioStartTmCount ( Id , 0 )
 

C, C++

long Ret;
Ret = AioStartTmCount ( Id , 0 );
 

C#

int Ret;
Ret = aio.StartTmCount ( Id , 0 );
 

Python

Ret = ctypes.c_long()
Ret.value = caio.AioStartTmCount ( Id , 0 )
 

See also

AioStopTmCount