Retrieves the current count value.
Ret = AioGetCntCount ( Id , CntChannel , Count )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the device ID retrieved from AioInit.
CntChannel
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Sets the counter channel.
Count
[ VB.NET : Integer ] [ C, C++ : long * ] [ C# : out int ] [ Python : ctypes.POINTER(ctypes.c_long)
]
Specifies the address of the variable that stores the current count value.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
15220 |
The value of CntChannel is outside the designated range of the function |
15221 |
Pointer
to Count is NULL |
20001 |
This function can't be used by this device |
20003 |
Can
not use because another process is using the device |
25220 |
The value of CntChannel is outside the designated range of the device being used |
Count = 0
This function cannot be used on devices without
counter functionality.
Even if the device is in operation, the function can be performed.
Retrieves the current count value for channel 0.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |