AioGetAoTransferMode


Function

Retrieves the transfer mode of the analog output conversion data. 

Format

Ret = AioGetAoTransferMode ( Id , AoTransferMode )

Parameters

Id [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short ]
Specifies the ID retrieved from AioInit function.

AoTransferMode [ VB.NET : Short ] [ C, C++ : short * ] [ C# : out short ] [ Python : ctypes.POINTER(ctypes.c_short) ]
Specifies the address of the variable that stores the transfer mode of the conversion data.

0

Device buffer mode

1

User buffer mode

Return value

Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]

Return values

Content

0

Normality completion

7

Execute AioResetDevice function because the device has recovered from standby mode

10001

Invalid Id was specified
Use the Id retrieved from AioInit to specify the Id in this function.

10002

AIO driver can't be called
At first, perform AioInit function.

13590

Pointer to AoTransferMode is NULL
Specify the address of variable to parameter.

20001

This function can't be used by this device

20002

Can not use while by another device works
To use this function, analog output operation must be stopped.

20003

Can not use because another process is using the device
When another process is using the device, all functions except for those that support multi-process can not be performed.

Initial value

In  all devices, AoTransferMode = 0

Remarks

This function cannot be used on devices without the analog output function.
If the device is in operation, the function cannot be performed.

Specifications based on devices

AIO-163202G-PE
AIO-163202UG-PE
AIO-123202G-PE
AIO-123202UG-PE
AIO-163202F-PE
ADA16-32/2(PCI)F

Returns AoTransferMode = 0 or 1.

AIO-160802L-LPE
ADA16-8/2(LPCI)L
ADAI16-8/2(LPCI)L
AIO-160802LI-PE

AoTransferMode = 0 is fixed.

AO-1604L-LPE
DA16-16(LPCI)L
DA16-8(LPCI)L
DA16-4(LPCI)L
DAI16-4(LPCI)L
AO-1604LI-PE
AO-1608L-LPE
AO-1616L-LPE
AO-1604LX-USB

AoTransferMode = 0 is fixed.

DA12-16(PCI)
DA12-8(PCI)
DA12-4(PCI)
AO-1604CI3-PCI
DEMO DEVICE

AoTransferMode = 0 is fixed.

Example

Retrieves the transfer mode of the analog output conversion data.

VB.NET

Dim Ret As Integer
Dim AoTransferMode As Short
Ret = AioGetAoTransferMode ( Id , AoTransferMode )
 

C, C++

long Ret;
short AoTransferMode;
Ret = AioGetAoTransferMode ( Id , &AoTransferMode );
 

C#

int Ret;
short AoTransferMode;
Ret = aio.GetAoTransferMode ( Id , out AoTransferMode );
 

Python

Ret = ctypes.c_long()
AoTransferMode = ctypes.c_short()
Ret.value = caio.AioGetAoTransferMode ( Id , ctypes.byref(AoTransferMode) )