Retrieves the repeat times.
Ret = AioGetAoRepeatTimes ( Id , AoRepeatTimes )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AoRepeatTimes
[ VB.NET : Integer ] [ C, C++ : long * ] [ C# : out int ] [ Python : ctypes.POINTER(ctypes.c_long)
]
Specifies the address of the variable that stores the repeat times.
0 |
Repeat action is repeated infinitely |
1 to 4294967295 |
Repeat action is performed specified times |
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
13170 |
Pointer
to AoRepeatTimes is NULL |
20001 |
This function can't be used by this device |
20002 |
Can
not use while by another device works |
20003 |
Can
not use because another process is using the device |
In all devices, 1
Repeat action is the action that is performed
repeat times from the generating start to stop.
If the memory type is FIFO, this settings have no meaning.
This function cannot be used on devices without
the analog output function.
If the device is in operation, the function cannot be performed.
Retrieves the repeat times.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |
AioSetAoRepeatTimes AioGetAoRepeatCount