Sets the analog output range for all channels.
Ret = AioSetAoRangeAll ( Id , AoRange )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AoRange
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the analog output range from the following range with macro or
value.
The available value differs by the device.
Range |
Macro |
Value |
-10 to 10V |
PM10 |
0 |
-5 to 5V |
PM5 |
1 |
-2.5 to 2.5V |
PM25 |
2 |
-1.25 to 1.25V |
PM125 |
3 |
0 to 10V |
P10 |
50 |
0 to 5V |
P5 |
51 |
0 to 2.5V |
P25 |
53 |
0 to 1.25V |
P125 |
54 |
0 to 20mA |
P20MA |
100 |
4 to 20mA |
P4TO20MA |
101 |
1 to 5V |
P1TO5 |
150 |
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
13120 |
The value of AoRange is outside the designated range of the function |
20001 |
This function can't be used by this device |
20002 |
Can
not use while by another device works |
23120 |
The value of AoRange is outside the designated range of the device being used |
It differs by the device type.
If the range is set by software, the initial value is the status when each
device is powered on.
If the range is set by jumper, the initial value is the factory settings.
This function cannot be used on devices without
the analog output function.
If the device is in operation, the function cannot be performed.
AIO-163202G-PE |
The range is
only changed by performing the function. The output value will
be 0V when this function is executed. |
AIO-163202F-PE |
The range is
only changed by performing the function. |
AIO-160802L-LPE |
-10 to 10V is fixed. |
AO-1604L-LPE |
-10 to 10V is fixed. |
DA12-16(PCI) |
The range is
only changed by performing the function. |
AO-1604CI3-PCI |
The range is
only changed by the JP settings. |
AIO-160802AY-USB |
-10 to 10V is fixed. |
AIO-163202FX-USB |
The range is
only changed by performing the function. |
AIO-121602LN-USB |
The range is
only changed by performing the function. |
AO-1604VIN-USB |
-10 to 10V is fixed. |
AO-1604AIN-USB |
0 to 20mA is fixed. |
AD12-16(PCI)EV |
The range is
only changed by the JP settings. |
AD16-16(PCI)EV |
The range is
only changed by the JP settings. |
DEMO DEVICE |
All ranges can
be set. Initial value is AoRange = 0. |
CPS-AO-1604LI |
0 to 20mA is fixed. |
CPS-AO-1604VLI |
-10 to 10V is fixed. |
CPSN-AO-1602LC |
The range is
only changed by performing the function. |
All the channel ranges are set to -10 to 10V.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |