Retrieves the data transfer times when the
"Event that the specified number of data are transferred" is
used.
This settings is necessary when the transfer mode of the conversion data
that is set by AioSetAoTransferMode function is User buffer mode.
This function needn't be executed if the transfer mode of the conversion
data is Device buffer.
Ret = AioGetAoEventTransferTimes ( Id , AoTransferTimes )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AoTransferTimes
[ VB.NET : Integer ] [ C, C++ : long * ] [ C# : out int ] [ Python : ctypes.POINTER(ctypes.c_long)
]
Specifies the address of the variable that stores the data transfer times
when the event raises.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
13670 |
Pointer
to AoSamplingTimes is NULL |
20001 |
This function can't be used by this device |
20002 |
Can
not use while by another device works |
20003 |
Can
not use because another process is using the device |
In all devices, AoTransferTimes = 500
This function cannot be used on devices without
the analog output function.
If the device is in operation, the function cannot be performed.
Retrievers the data transfer times when the "Event that the specified number of data are transferred" is used.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |