Retrieves the number of channels for the analog output conversion.
Ret = AioGetAoChannels ( Id , AoChannels )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AoChannels
[ VB.NET : Short ] [ C, C++ : short * ] [ C# : out short ] [ Python :
ctypes.POINTER(ctypes.c_short) ]
Specifies the address of the variable that stores the number of channels.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
13070 |
Pointer
to AoChannels is NULL |
20001 |
This function can't be used by this device |
20003 |
Can
not use because another process is using the device |
One channel is used for all devices.
This function cannot be used on devices without
the analog output function.
This function can be executed even if the device is in operation.
Retrieves the number of channels for the analog output conversion.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |
AioSetAoChannels AioGetAoMaxChannels