Sets the level when the conversion stop condition 
 is Level comparison. Level settings are stored in Voltage or Current.
This settings is necessary when the conversion stop condition that is set 
 by AioSetAiStopTrigger function is the level comparison.
It isn't necessary to be set except for the conversion stop condition is 
 the level comparison.
Only one level comparison setting can be set for one device. If specified multiple times, only the last data is valid.
Ret = AioSetAiStopLevelEx ( Id , AiChannel , AiStopLevel , AiDirection )
Id 
 [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short 
 ]
Specifies the ID retrieved from AioInit function.
AiChannel 
 [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short 
 ]
Specifies the channel that performs the level comparison.
AiStopLevel 
 [ VB.NET : Single ] [ C, C++ : float ] [ C# : float ] [ Python : ctypes.c_float 
 ]
Sets the data that performs the level comparison in voltage or current.
AiDirection 
 [ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short 
 ]
Sets the direction of the level comparison from the following range.
| 0 | Both edges | 
| 1 | Rising edge | 
| 2 | Falling edge | 
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
| Return values | Content | 
| 0 | Normality completion | 
| 7 | Execute AioResetDevice function because the device has recovered from standby mode | 
| 10001 | Invalid 
		 Id was specified | 
| 10002 | AIO 
		 driver can't be called | 
| 11940 | The 
		 value of AiChannel is outside the designated range of the function | 
| 11941 | The 
		 value of AiDirection is outside the designated range of the function | 
| 20001 | This function can't be used by this device | 
| 20002 | Can 
		 not use while by another device works | 
| 20003 | Can 
		 not use because another process is using the device | 
| 21940 | The value of AiChannel is outside the designated range of the device being used | 
| 21941 | The value of AiStopLevel is outside the designated range of the device being used | 
| 21943 | The value of AiDirection is outside the designated range of the device being used | 
In all devices, AiChannel = 0, AiDirection = 0
| Resolution of device is 12 bit | AiStopLevel = Voltage or Current value equals to 800H in binary value | 
| Resolution of device is 16 bit | AiStopLevel = Voltage or Current value equals to 8000H in binary value | 
This function cannot be used on devices without 
 the analog input function.
If the device is in operation, the function cannot be performed.
Stops channel 0 by the 
 level comparison.
Level data is 5.0V, Level direction is both edges.
| VB.NET | Dim 
		 Ret As Integer | 
| C, C++ | long 
		 Ret; | 
| C# | int 
		 Ret; | 
| Python | Ret 
		 = ctypes.c_long() |