Retrieves the sampling count when the stop
trigger is input.
This function can only be used when the transfer mode of the conversion
data that is set by AioSetAiTransferMode is Device buffer mode.
It cannot be used when the transfer mode of the conversion data is User
buffer mode.
Ret = AioGetAiStopTriggerCount ( ID , AiStopTriggerCount )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AiStopTriggerCount
[ VB.NET : Integer ] [ C, C++ : long * ] [ C# : out int ] [ Python : ctypes.POINTER(ctypes.c_long)
]
Specifies the address of the variable that stores the input location of
stop trigger.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
11560 |
Pointer
to AiStopTriggerCount is NULL |
20001 |
This function can't be used by this device |
20003 |
Can
not use because another process is using the device |
In all devices, AiStopTriggerCount = 0
The retrieved value by calling this function is overwritten when input stop condition of the next stop trigger is satisfied.
Resets this value to 0 by calling AioResetAiMemory function.
This function cannot be used on devices without
the analog input function.
This function can be executed if the device is working.
Retrieves the sampling count when the stop trigger is input.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |