Resets the device memory or software memory.
This function can only be used when the transfer mode of the conversion
data that is set by AioSetAiTransferMode is Device buffer mode.
It cannot be used when the transfer mode of the conversion data is User
buffer mode.
Ret = AioResetAiMemory ( Id )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
20001 |
This
function can't be used by this device |
20002 |
Can not use while by another device works |
20003 |
Can
not use because another process is using the device |
When this function is executed, the following status are reset.
•Memory
management pointer (read pointer and write pointer) are reset to 0.
•The
repeat count is reset to 0.
•The
sampling count when the stop trigger is input is reset to 0.
•Buffer
"Overflow" status is reset.
•"The
specified number of data are stored" status is reset.
This function cannot be used on devices without
the analog input function.
If the device is in operation, the function cannot be performed.
Resets the device memory or software memory.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |