Retrieves the conversion speed.
Ret = AioGetAiScanClock ( Id , AiScanClock )
Id
[ VB.NET : Short ] [ C, C++ : short ] [ C# : short ] [ Python : ctypes.c_short
]
Specifies the ID retrieved from AioInit function.
AiScanClock
[ VB.NET : Single ] [ C, C++ : float * ] [ C# : out float ] [ Python :
ctypes.POINTER(ctypes.c_float) ]
Specifies the address of the variable that stores the conversion speed.
Ret [ VB.NET : Integer ] [ C, C++ : long ] [ C# : int ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid
Id was specified |
10002 |
AIO
driver can't be called |
12250 |
Pointer
to AiScanClock is NULL |
20001 |
This function can't be used by this device |
20002 |
Can
not use while by another device works |
20003 |
Can
not use because another process is using the device |
The fastest conversion speed is set for each device.
This function cannot be used on devices without
the analog input function.
If the device is in operation, the function cannot be performed.
Retrieves the conversion speed that is set.
VB.NET |
Dim
Ret As Integer |
C, C++ |
long
Ret; |
C# |
int
Ret; |
Python |
Ret
= ctypes.c_long() |