Our USB I/O Unit–Module Type is a device that is connected to PC via
a USB cable.
The USB I/O unit is used by attaching a CONPROSYS nano I/O module.
Each CONPROSYS nano I/O module is accessed via a USB cable.
Please note that the installation procedure is different from the general USB devices.
The USB I/O Unit–Module
Type does not automatically recognize devices when connected with
a USB cable.
Therefore, it is necessary to perform the [Add legacy hardware] operation
in Device Manager in advance.
Start Device Manager and select
the PC name at the top of the tree view.
From the menu, select [Action] - [Add legacy hardware].
[Welcome to Add Hardware
Wizard] dialog is displayed as shown below.
Click [Next >].
[The wizard can help you
install other hardware] dialog is displayed.
Select [Install the hardware that I manually select from a list] and
click [Next >].
[From the list below, select
the type of hardware you are installing] dialog is displayed.
Select [CONTEC Devices] from the list and click [Next >].
If [CONTEC Devices] is not displayed in the list, select [Show All
Devices] and click [Next >].
When the device list appears, select [CONTEC] under [Manufacturer].
[Select the device driver
you want to install for this hardware] dialog is displayed.
Select [*** ***-USB-MODULE1] from the list and click [Next >].
※ *** is the driver category name such as AIO and DIO.
[Completing the Add Hardware
Wizard] dialog is displayed.
Click [Finish] to complete the installation of the USB I/O Unit–Module
Type.
The USB I/O Unit–Module Type is attached a CONPROSYS
nano I/O module.
For details on how to attach the I/O module, please refer to the reference
manual for each hardware device.
Connect the power cable to the USB I/O Unit–Module
Type and start the device.
For details on connection methods, please refer to the reference manual
for each hardware device.
Connect the PC and the USB I/O unit with a USB cable
while the OS is running.
For details on connection methods, please refer to the reference manual
for each hardware device.
Once connected with USB cable, the device installation
will be performed automatically.
Please set and confirm the device name
before using the device.
Please register [*** ***-USB-MODULE1]
only once for each USB I/O unit.
There is no need to perform this procedure multiple times depending on
the number of CONPROSYS nano I/O modules.
Example: If you connect the I/O modules "CPSN-DI-08L" and "CPSN-DO-08L",
after
registering "DIO DIO-USB-MODULE1" once, there is no need to