Select the device for which you want to change the DeviceName.
At the "Please input" prompt, specify the number in [] of the
target device.
Enter the number of the target device, information about the selected device
will be displayed, and wait for command selection.
The commands that can be executed depend on the target device.
Select the command "[1]:Change DeviceName"
to change the DeviceName of the selected device.
Select the command "[m]:Back to menu", the (Devices list) menu
will be displayed again, and wait for command selection.
It can not have the same name as any other device.
When specifying a device from an application, specify this DeviceName.
Configure the wired LAN network
Make settings related to 920MHz wireless communication.
Item name |
Description |
Wireless Channel |
Set the channel used for 920 MHz band communication. |
PAN ID |
Set the PAN ID used for 920 MHz band communication. |
Tx Power |
Set transmission output. |
Bit Rate |
Set the bit rate (communication speed). |
Request Timeout |
Set the communication timeout time between the master unit
and slave unit. |
Aging Time |
Set the connection maintenance time between the master and
slave. Normally, use the default value, but if you have changed Data
Interval setting, Also, when changing this setting, it is recommended to set the
same setting for the master unit. |
Encryption Key |
Set the encryption key used for communication between the master unit and the slave unit. It is specified with 32 digit hexadecimal number, and the initial
value is all 0. |
Priority Route |
If there is a communication route you want to prioritize,
specify the target Device ID. If you want to communicate directly with the master unit, specify
the target Device ID of Gateway. - Disabled Do not specify a preferred route |
Configure the fail-safe function.
Item name |
Description |
Event Trigger |
Sets the condition to activate fail-safe state. Linkdown is conditional on link down of the network such as
disconnection of the LAN cable. |
Failsafe OutBit |
Set the output terminal to output with the fail-safe function. Setting example: |
Pattern Setting |
Set the output data to be output with the fail-safe function. Setting example: |
Start wait time |
Set the time to disable the fail-safe function after turning
on the power. |
Set whether to allow Event Notify Function
(UDP:0x501F) in Firewall settings.
If unregistered, the event notification function of the ETH device will
not be available.
If registered, the port on the PC side will be released and connections
from the ETH device UDP:0x501F will be allowed.
When an ETH device is detected, the ETH device UDP:0x501F is allowed by default.
Item name |
Description |
DI Count |
Select Enabled to start the digital input counter function
when the device starts up. |
Count Edge |
Select the direction in which you want to count the digital inputs. |
Unit ID |
When using the same product, it is necessary to set the Unit ID uniquely. |
Device ID |
When using several slave units with one master unit, it is necessary to set the Device ID uniquely. |
Digital Filter |
Set the digital filter value at power on of this device. When using this device with API-DIO(LNX) driver, it is possible to set the digital filter at any time by API function separately from this setting. |
Data Interval |
Sets the time interval at which the input value of this device is transmitted to its master unit. |
Device Mode |
Normally it is used in the initial value "Wireless I/O mode". Select "CONPROSYS mode" when using it as a slave of
our product CONPROSYS series. |
Modbus Function |
Set enable / disable of Modbus function. It is compatible with Modbus TCP Slave and can collect and control
data from upper communication equipment with Modbus master function. |