Retrieves the pulse measurement settings for the specified channel.
Ret = DioGetPulseMeasurementSetting( Id , ChNo , ChNum , MeasurementTarget , PulsePeriod )
Id [ C, C++: short ] [ Python: ctypes.c_short ]
Specify the device ID retrieved from DioInit.
ChNo [ C, C++: short * ] [ Python: ctypes.POINTER(ctypes.c_short) ]
Specify the start address of the array that stores the channel numbers for which settings are to be retrieved.
ChNum [ C, C++: short ] [ Python: ctypes.c_short ]
Specify the number of channels specified in ChNo.
MeasurementTarget [ C, C++: unsigned short * ] [ Python: ctypes.POINTER(ctypes.c_ushort) ]
Specify the start address of the array that stores the pulse measurement time settings.
PulsePeriod [ C, C++: unsigned short * ] [ Python: ctypes.POINTER(ctypes.c_ushort) ]
Specify the start address of the array that stores the pulse measurement period.
Ret [ C, C++: long ] [ Python: ctypes.c_long ]
|
Definition |
Value [Dec] |
Description |
|
DIO_ERR_SUCCESS |
0 |
Normal completed. |
|
DIO_ERR_DLL_INVALID_ID |
10001 |
Invalid ID specified. |
|
DIO_ERR_DLL_CALL_DRIVER |
10002 |
Driver cannot be called (failed in ioctl). |
|
DIO_ERR_DLL_BUFF_ADDRESS |
10100 |
Invalid data buffer address. |
|
DIO_ERR_SYS_NOT_SUPPORTED |
20001 |
This board couldn't use this function. |
|
DIO_ERR_SYS_CH_NO |
20105 |
Channel No. is outside the setting range. |
|
DIO_ERR_SYS_CH_NUM |
20106 |
Channel number is outside the setting range. |
The others (See also: Details of Error Code)
Retrieves the pulse measurement settings for the specified channel.
Get the pulse measurement settings for channel 0 and channel 1.
|
C, C++ |
long Ret; |
|
Python |
Ret = ctypes.c_long() |