DioGetMaxPwmChannels


Function

Retrieves the total number of PWM output channels of the device.

Format

Ret = DioGetMaxPwmChannels ( Id , ChannelNum )

Parameters

Id [ C, C++: short ] [ Python: ctypes.c_short ]
Specify the device ID retrieved from DioInit.

ChannelNum [ C, C++: unsigned short * ] [ Python: ctypes.POINTER(ctypes.c_ushort) ]
Specify the address of the variable to obtain the number of PWM output channels.

Return Value

Ret [ C, C++: long ] [ Python: ctypes.c_long ]

Definition

Value

[Dec]

Description

DIO_ERR_SUCCESS

0

Normal completed.

DIO_ERR_DLL_INVALID_ID

10001

Invalid ID specified.

DIO_ERR_DLL_CALL_DRIVER

10002

Driver cannot be called (failed in ioctl).

DIO_ERR_DLL_BUFF_ADDRESS

10100

Invalid data buffer address.

DIO_ERR_SYS_NOT_SUPPORTED

20001

This board couldn't use this function.

DIO_ERR_SYS_CH_NO

20105

Channel No. is outside the setting range.

DIO_ERR_SYS_CH_NUM

20106

Channel number is outside the setting range.

DIO_ERR_SYS_DEVICE_ERR_DRIVER_IC_ERR

21200

Driver IC error occurred.

DIO_ERR_SYS_DEVICE_ERR_PCOM_FAILURE

21201

PCOM power failure occurred.

The others (See also: Details of Error Code)

Example

Retrieves the total number of PWM output channels of the device.

C, C++

long Ret;
unsigned short ChannelNum;

Ret = DioGetMaxPwmChannels( Id , &ChannelNum );
 

Python

Ret = ctypes.c_long()
ChannelNum = ctypes.c_ushort()

Ret.value = cdio.DioGetMaxPwmChannels( Id , ctypes.byref(ChannelNum) )
 

See Also

None