Wait for the start trigger (Analog Output)

If conversion start condition is set to External trigger rising edge/External trigger falling edge/Level comparison by function AioSetAoStartTrigger, this status is ON from performing function AioStartAo to the moment that the start trigger is input.
As the start trigger is input and the conversion starts, this status turns OFF.
If repeat operation is set by "Repeat", this status turns ON each time the state becomes to be waiting for the conversion start condition.