Function
Sets the data transfer times when the "Event that the specified number of data are transferred" is used.
This settings is necessary when the transfer mode of the conversion data that is set by AioSetAoTransferMode function is User buffer mode.
This function needn't be execute if the transfer mode of the conversion data is Device buffer.
Format
Ret = AioSetAoEventTransferTimes ( Id , AoTransferTimes )
Parameters
Id [ C, C++ : short ] [ Python : ctypes.c_short ]
Specifies the Device ID retrieved from AioInit function.
AoTransferTimes [ C, C++ : long ] [ Python : ctypes.c_long ]
When the event factor is "Event that the specified number of data are transferred", Sets the data transfer times that cause the event to raise.
Return value
Ret [ C, C++ : long ] [ Python : ctypes.c_long ]
Return values |
Content |
0 |
Normality completion |
7 |
Execute AioResetDevice function because the device has recovered from standby mode |
10001 |
Invalid Id was specified |
10002 |
AIO driver can't be called |
13660 |
The value of AoTransferTimes is outside the designated range of the function |
20001 |
This function can't be used by this device |
20002 |
Can not use while by another device works |
20003 |
Can not use because another process is using the device |
Initial value
In all devices, 500
Remarks
This function cannot be used on devices without the analog output function.
If the device is in operation, the function cannot be performed.
Example
Sets 5000 to the transfer times when "Event that the specified number of data are transferred" is specified.
C, C++ |
long Ret; |
Python |
Ret = ctypes.c_long() |
See also